Cara mengetahui Code Error Ac Daikin dengan remote ini berlaku pada beberapa Ac Daikin. Cari eror code dengan remote pertama-tama buat tampilan pada display remote menjadi (00),
caranya dengan menekan dan tahan tombol cancel beberapa saat,setelah Display sudah menunjukan ( 00 ) ,kemudan arahkan remote indoor sambil tekan-lepas tombol cancel berkali hingga muncul kode errornya AO
Indoor Error of external protection device A1
Indoor PCB defect A3 Indoor Malfunction of drain Level control system A5
Indoor Freeze-up prevention A6
Indoor Fan motor lock, Overload A7
Indoor Malfunction of swing motor flap A9
Indoor Malfunction of EEV AF
Indoor Drain level above limit (clogging) AJ
Indoor Malfunction of capacity set device C3
Indoor Malfunction of drain thermistor C4
Indoor Malfunction of liquid pipe thermistor C5
Indoor Malfunction of gas pipe thermistor C7
Indoor Lower louvre limit switch/motor C9
Indoor Malfunction of air thermistor CC
Indoor Malfunction of moisture sensor CA
Indoor Malfunction of discharge air thermistor CJ
Indoor Malfunction of remote control thermistor CE
Indoor Malfunction of radiant heat sensor E0
Outdoor Activation of outdoor safety device E1
Outdoor PCB defect E3
Outdoor Activation of high pressure switch E4
Outdoor Activation of low pressure switch E5
Outdoor Activation of compressor over heat protection E5
Outdoor Compressor motor lock E6
Outdoor Compressor start up error E6
Outdoor Standard compressor lock/overcurrent E7
Outdoor Fan motor lock, Overload E8
Outdoor Inverter input overcurrent E9
Outdoor Malfunction of EEV EA
Outdoor Four way valve defective. F3
Outdoor Abnormal discharge pipe temperature F6 Outdoor Refrigerant overcharged FC
Outdoor Low pressure drop. H3
Outdoor High pressure switch defect H4
Outdoor Low pressure switch defect H6
Outdoor Compressor motor position detection sensor error H7
Outdoor Fan motor position detection sensor error H8
Outdoor Current transformer error H9
Outdoor Malfunction of air thermistor J1
Outdoor Malfunction of pressure sensor J2
Outdoor Current sensor malfunction J3
Outdoor Malfunction of discharge pipe thermistor J4
Outdoor Low pressure saturation thermistor J5
Outdoor Malfunction of suction pipe thermistor J6
Outdoor Malfunction of heat exchanger thermistor J7
Outdoor Malfunction of heat exchanger liquid thermistor J8
Outdoor Malfunction of liquid pipe thermistor J9
Outdoor Malfunction of gas pipe thermistor JA
Outdoor Malfunction of discharge pipe pressure sensor JC
Outdoor Malfunction of suction pipe pressure sensor JH
Outdoor Malfunction of oil temperature sensor L0
Outdoor Malfunction of inverter L3
Outdoor Electronic component box overheat L4
Outdoor Inverter cooling defect L5
Outdoor Comp motor ground fault, Short circuit L6
Outdoor Compressor motor grounding/short circuit L7
Outdoor Total input overcurrent L8
Outdoor Comp overload, Motor disconnected L9
Outdoor Compressor lock LA
Outdoor Power unit malfunction LC
Outdoor Transmission between inverter & outdoor P1
Outdoor Inverter over ripple P3
Outdoor Thermistor abnormality P4
Outdoor Power unit humidity sensor malfunction PJ
Outdoor Failure of capacity set resistor U0
System Shortage of refrigerant or EEV failure U1
System Negative phase, Open phase U2 System Power supply insufficient U3
System Wiring check operation not executed U3
System Mismatch of indoor and outdoor units (Split only) U4
System Transmission between indoor units U5
System Transmission to remote controller U6
System Malfunction transmission outdoor to BP unit U7
System Transmission between outdoor units U7
Outdoor Malfunction between outdoor boards(RMX/RX RK) U8
System Transmission between master & slave R/C U9
System Transmission error between indoor to outdoor UA
System Excessive number of fancoils UC
System Address duplication of central controllers UE
System Transmission error between indoor & central UF
System Refrigeration system not set/wiring – piping UF
System Terminals 1 and 3 crossed (Split/Skyair) UH
System System error, Refrigeration system set up M1
System PCB defect M8 System Transmission error between central controllers MA
System Improper combination of optional controllers MC
System Address duplication, Improper setting 64 VAM
Indoor unit air thermistor error 65 VAM Outside air thermistor error 68 VAM 6A VAM
Damper system alarm 6A VAM
Damper system and thermistor error 6F VAM
Malfunction of remote controller 6H VAM
Malfunction of door switch or connector 94 VAM
Internal transmission error Grey fault codes, system still runs,